Heat pump Daikin Comfora 35

In Stock
timer

1,498.54

5 in stock

NEW Daikin Comfora FTXTP-K air-to-air heat pump
Wall-mounted air-to-air heat pump that guarantees high efficiency and comfort even when the outdoor temperature drops to -25 degrees.
 
Why choose a Comfora air-to-air heat pump?
Laconic design and compact size
Daikin Comfora air-to-air heat pumps are very economical and have an energy efficiency class A ++. With the Daikin web app, you can control your equipment from anywhere in the world. Comfora series air-to-air heat pumps operate remarkably quietly. Have the fun of being at home without having to compromise!
An air to air heat pump suitable for any home
The compact size of the unit makes it ideal for renovation projects, especially for installation above the door
Seasonal Efficiency Values: Full A ++ Range in Cooling and Heating Mode
Guaranteed thermal power at low outdoor temperatures down to -25 degrees
Compact and fashionable wall-mounted air-to-air heat pump
Start saving today!
With the Daikin Comfora air-to-air heat pump you:
save on energy bills
think about the environment
take care of your family’s health and well-being
Top notch technology and energy efficiency
Daikin continually develops innovative, environmentally friendly and most efficient heat pump technologies to achieve the best energy efficiency and environmental friendliness.
Daikin Bluevolution technology uses R32 refrigerant, which significantly reduces CO2 emissions compared to competitors.
Daikin once again proves its leadership in providing the best heating solutions, as well as in respect of the environment.
Technical parameters of Daikin Comfora air-to-air heat pump
Fan speed modes
   – Allows you to select the fan speed up to the set parameter.
 
Working range down to -25 ° C
   “Daikin equipment is suitable for any climate and thanks to its operating range of -25 degrees, it works even in the harshest conditions.
Economy mode
   – Reduces current consumption, so you can switch on other high-consumption electrical appliances. This feature is also energy efficient.
Network controller using the app
   – Control the indoor unit using the app via the Internet from anywhere in the world.
Fan only
   – The equipment can be used as a fan that blows air without heating or cooling it.
Night mode
   – Saves energy and prevents the air from cooling or heating up excessively at night.
Powerful mode
   – Powerful mode can be selected for rapid heating or cooling; at the end of the powerful mode, the device returns to the previous mode.
 
Comfort mode
   – Provides air flow without strong draft so that warm or cold air does not blow directly onto the person.
 
Silent operation of the indoor unit
   – The Silent button on the remote control reduces the noise level by 3 dB (A).
 
Automatic changeover between cooling and heating modes
   – Automatically selects heating or cooling mode according to the set temperature.
Automatic fan speed
   – To reach or maintain the set temperature, the system automatically selects the required fan speed mode.
 
Dry program
   – Allows you to lower the humidity level without changing the room temperature.
Energy saving in standby mode
   – Power consumption is reduced in standby mode by about 80%. If the sensor does not detect the presence of a person within 20 minutes, the system automatically switches to power saving mode.
 
Automatic vertical change of direction
   – Allows you to select the automatic vertical change of louver grille to make indoor air cooling more efficient.
 
Titanium Apatite Deodorizing Filter
   – The filter removes dust particles, harmful organic chemicals, bacteria, viruses and allergens, and neutralizes odors such as tobacco or pets.
 
24 hour timer
   – Allows you to program the start of work at any time within 24 hours.
 
Remote control with cable
   – Starts, stops and regulates the air conditioner.
Remote control with infrared port
   – Starts, stops and controls the air conditioner from a distance.
Automatic reboot
   – The equipment restarts after a power failure automatically with factory settings.
Self-diagnosis
   – Simplifies maintenance by showing system errors or malfunctions.
 

 

Product Type

, , , , ,

Brand

Model

Installation Type

Application

,

Recommended Area (m²)

Min. Cooling Power (kW)

Max. Cooling Power (kW)

Min. Heating Power (kW)

Max. Heating Power (kW)

Rated Electricity Consumption for Cooling (kW)

Rated Electricity Consumption for Heating (kW)

SEER

SCOP

Cooling energy efficiency class

Heating energy efficiency class

Min. capacity (m³/h)

234

Max. capacity (m³/h)

Min. Indoor Unit Noise Level (dB)

Max. Indoor Unit Noise Level (dB)

Indoor Unit Dimensions LxWxH (mm)

Outdoor Unit Dimensions LxWxH (mm)

Indoor Unit Weight

Outdoor Unit Weight

Refrigerant Pipe Diameter for Liquid (inch)

Refrigerant piping diameter for gas (inch)

Refrigerant Type

Number of Units (pcs)

Features

, , , , , , ,

Max. Communication Length (m)

Max. Elevation Difference (m)

Min. Outdoor Air Temperature for Cooling (°C)

Max. Outdoor Air Temperature for Cooling (°C)

Min. Outdoor Air Temperature for Heating (°C)

Max. Outdoor Air Temperature for Heating (°C)

Voltage (V)

Phase (Ph)

Frequency (Hz)

Circuit breaker (A)

Technical Data

indoor unit FTXTP 35M
Dimensions unit HeightxWidthxDepth mm 286x770x225
Weight unit kg 9.00
air filter type Removable / washable
fan Air flow rate cooling Silent operation/Low/Medium/High m³/min 3.9 /5.5 /8.3 /11.5
heating Silent operation / Low / Medium / High m³/min 4.5 / 5.6 / 8.7 / 11.5
sound power level cooling dBA 58
heating dBA 58
sound pressure level cooling Silent operation/Low/High dBA 21/26/43
heating Silent operation/Low/High dBA 21/26/43
Control systems infrared remote control ARC480A53
wired remote control BRC944B2 / BRC073A1
Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal)
| See separate drawing for electrical data

 

outdoor unit RXTP 35R
Dimensions unit HeightxWidthxDepth mm 551x763x312
Weight unit kg 38
sound power level cooling 61
sound pressure level cooling Nom. dBA 48
heating Nom. dBA 49
operation range cooling Ambient Min.~Max. °CDB -10 ~46
heating Ambient Min.~Max. °CWB -25~18
Refrigerator type R-32
GWP 675
charge kg/TCO2Eq 1.1/-
Piping connections Liquid OD mm 6.35
Gas OD Max. mm 9.50
Piping length OU-IU m 20
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)
Level difference  IU-OU  Max. m 15
power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240
Current – 50Hz Maximum fuse amps (MFA) A sixteen
Contains fluorinated greenhouse gases | See separate drawing for operation range | See separate drawing for electrical data

 

efficiency data FTXTP+RXTP 35M+35R
Cooling capacity Min./Nom./Max. kW 0.80 /3.50 /4.40
heating capacity Min./Nom./Max. kW 1.20 /4.00 /6.70
power input cooling Nom. kW 0.92
heating Nom. kW 0.90
space cooling energy efficiency class A++
Capacity pdesign kW 3.50
SEER 7.20
Annual energy consumption kWh/a 170
Space heating (Average climate) energy efficiency class A++
Capacity pdesign kW 3.00
SCOP/A 4.81
Annual energy consumption kWh/a 873
Space heating (Cold climate) energy efficiency class A
Capacity Pdesignh kW 4.38
Annual energy consumption kWh/a 2.394
SCOP/C 3.84
Nominal efficiency EER 3.80
COP 4.44
Annual energy consumption kWh 461
Energy labeling Directive Cooling/Heating A/A