Heat pump Daikin Perfera 30

In Stock
timer

1,627.06

5 in stock

Attractive, wall mounted design with perfect indoor air quality down to -25°!

  • Guaranteed heating capacity at low ambient temperature, down to -25°C
  • Seasonal efficiency values up to A+++ in cooling and heating
  • When installed close to a heating device (e.g. fire place or oven) and the set temperature is reached, the fan keeps on running to have an even temperature throughout the whole house
  • Heat boost quickly heats up your home when starting up your air conditioner. Set temperature is reached 14% faster than a regular air conditioner (pair only)
  • Using electrons to trigger chemical reactions with air borne particles, the Flash Streamer breaks down allergens such as pollen and fungal allergens and removes bothersome odours providing a better, cleaner air
  • Silver allergen removal and air purifying  filter captures allergens such as pollen to ensure a steady supply of clean air
  • Daikin Residential controller (optional): control your indoor from any location with an app, via your local network or internet.
  • Voice command via Amazon Alexa or Google Assistant to control main functions such as set point, operation mode, fan speed, etc
  • Quiet operation: down to 19dBA sound pressure level
  • 3-D air flow combines vertical and horizontal auto swing to circulate a stream of warm or cool air right to the corners of even large spaces
  • Sleek, unobtrusive air conditioning unit that matches European sensibilities regarding interior design
  • Choosing for an R-32 product, reduces the environmental impact with 68% compared to R-410A and leads directly to lower energy consumption thanks to its high energy efficiency
  • 2 area motion detection sensor: air flow is sent to a zone other than where the person is located at that moment; if no people are detected, the unit will automatically switch over to the energy-efficient setting.
Product Type

, , , , ,

Brand

Model

Installation Type

Application

,

Recommended Area (m²)

Min. Cooling Power (kW)

Max. Cooling Power (kW)

Min. Heating Power (kW)

Max. Heating Power (kW)

Rated Electricity Consumption for Cooling (kW)

Rated Electricity Consumption for Heating (kW)

SEER

SCOP

Cooling energy efficiency class

Heating energy efficiency class

Min. capacity (m³/h)

240

Max. capacity (m³/h)

Min. Indoor Unit Noise Level (dB)

Max. Indoor Unit Noise Level (dB)

Indoor Unit Dimensions LxWxH (mm)

Outdoor Unit Dimensions LxWxH (mm)

Indoor Unit Weight

Outdoor Unit Weight

Refrigerant Pipe Diameter for Liquid (inch)

Refrigerant piping diameter for gas (inch)

Refrigerant Type

Number of Units (pcs)

Features

, , , , , , ,

Max. Communication Length (m)

Max. Elevation Difference (m)

Min. Outdoor Air Temperature for Cooling (°C)

Max. Outdoor Air Temperature for Cooling (°C)

Min. Outdoor Air Temperature for Heating (°C)

Max. Outdoor Air Temperature for Heating (°C)

Voltage (V)

Phase (Ph)

Frequency (Hz)

Circuit breaker (A)

Technical Data

indoor unit FTX™ 30 r 40 r
Dimensions Unit ism HeightxWidthxDepth mm 295 x 778 x 272 299 x 998 x 292
Weight Unit ism kg 10.0 May 14
Air filter Type Removable / washable Removable / washable
Fan Air consumption Cooling Quiet/Low/m³/min 4.1 /5.3 /7.8 /12.2 4.6 /5.8 /9.5 /15.4
medium height
Heating Quiet operation / m³/min 4.0 / 4.9 / 7.5 / 12.5 5.9 / 7.1 / 10.5 / 17.5
Low Medium High
Sound power level Cooling dBA 60.0 60.0
Heating dBA 61.0 61.0
Sound pressure Cooling Quiet/Low/High dBA 21.0 /25.0 /45.0 20.0 /24.0 /46.0
level Heating Quiet/Low/High dBA 19.0 /22.0 /45.0 19.0 /22.0 /46.0
Control systems infrared remote control ARK466A75 ARK466A75
Wired remote control BRC073A1 BRC073A1

 

Outdoor unit RXTM 30 r 40 r
Dimensions Unit HxWxD mm 551 x 763 x 312
Weight Unit kg 38
Sound power level Cooling 61
Sound pressure Cooling Nom. dBA 48
level Heating Nom. dBA 49
Working range Ambient temperature Min.~Max. °CDB -10 ~46
Ambient temperature min.~max. °CWB -25~18
Refrigerant Type R-32
PGP 675
Refueling kg/TCO2eq. 1.1/-
Piping connections Liquid OD mm 6.35
Outer diameter of gas mm 9.50
Piping length OU – IU Max. m 20
Additional refrigerant charge kg/m 0.02 (for pipelines longer than 10 m)
Level difference IU – OU Max. m 15
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240
Current – 50 Hz Maximum fuse amps (MFA) A sixteen

 

FTXTM + RXTM performance data 30p + 30p 40p + 40p
Cooling capacity Min./Nom./Max. kW 0.70 /3.00 /4.50 0.90 /4.00 /5.10
Heating capacity Min./Nom./Max. kW 0.80 /3.20 /6.70 1.20 /4.00 /7.20
Input power Cooling Surname. kW 0.73 1.08
Heating Surname. kW 0.60 0.74
Room cooling Energy efficiency class A++
Capacity Design kW 3.00 4.00
VIDYASCHIY 7.60 7.7
Annual energy consumption kWh/year 138 182
Space heating (average climate) Energy efficiency class A+++
Capacity Design kW 3.00 3.80
PURPOSE/A 5.12 5.30
Annual energy consumption kWh/year 821.00 1.00
Space heating (cold climate) Energy efficiency class A+
Capacity Design kW 4.38 5.55
Annual energy consumption kWh/year 2.28 2.80
FUNCTION/S 4.04 4.16
Rated efficiency  HONOUR 4.10 3.71
KS 5.34 5.37
Annual energy consumption kWh 366 539
Energy efficiency label Cooling/heating directive A/A